1.Input parameter:
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Input Voltage | V(AC) | Normal | 85 | 220 | 265 |
Input frequency | HZ | Normal | 50 | 50 | 60 |
Power factor | PF | Normal | 0.428 | 24.22 | 24.49 |
Input Inrush Current | A | Cold start under normal conditions |
Parameters | Unit | Minimum | Typical | Maximum |
Output current | MA | 100 | 2500 | 2500 |
Output voltage | V | 23.99 | 24.22 | 24.49 |
Output ripple | MV | |||
Constant current accuracy | % | 1% | 3% | 5% |
AC Input | Output | ||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency |
110 | 71.32 | 23.99 | 2500 | 0.721 | 0.84 |
120 | 70.88 | 24.02 | 2500 | 0.715 | 0.85 |
170 | 69.89 | 24.09 | 2500 | 0.744 | 0.86 |
200 | 70.29 | 24.16 | 2500 | 0.726 | 0.86 |
220 | 70.39 | 24.16 | 2500 | 0.714 | 0.86 |
240 | 70.29 | 24.05 | 2500 | 0.703 | 0.86 |
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Working ambient temperature | ºC | Full load operation | -18 | +40 | +60 |
Storage ambient temperature | ºC | -25 | 25 | +75 |