1.Input parameter:
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Input Voltage | V(AC) | Normal | 100 | 220 | 240 |
Input frequency | HZ | Normal | 43 | 50 | 65 |
Power factor | PF | Normal | 0.614 | 0.637 | 0.691 |
Input Inrush Current | A | Cold start under normal conditions |
Parameters | Unit | Minimum | Typical | Maximum |
Output current | MA | 0 | *** | 2400 |
Output voltage | V | 5 | 5.19 | 5.3 |
Output ripple | MV | |||
Constant current accuracy | % | 1% | 3% | 5% |
AC Input | Output | ||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency |
100 | 15.9 | 5.08 | 2400 | 0.688 | 0.77 |
110 | 15.9 | 5.17 | 2400 | 0.689 | 0.78 |
120 | 15.8 | 5.18 | 2400 | 0.691 | 0.79 |
170 | 15.4 | 5.19 | 2400 | 0.667 | 0.81 |
200 | 15.3 | 5.19 | 2400 | 0.649 | 0.81 |
220 | 15.3 | 5.19 | 2400 | 0.637 | 0.81 |
240 | 15.3 | 5.19 | 2400 | 0.626 | 0.81 |
265 | 15.3 | 5.19 | 2400 | 0.614 | 0.81 |
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Working ambient temperature | ºC | Full load operation | -18 | +40 | +60 |
Storage ambient temperature | ºC | -25 | 25 | +75 |