Parameters | Unit | Test description | Minimum | Typical | Maximum |
Input Voltage | V(AC) | Normal | 100 | 220 | 265 |
Input frequency | HZ | Normal | 43 | 50 | 65 |
Power factor | PF | Normal | 0.463 | 0.6 | 0.646 |
Input Inrush Current | A | Cold start under normal conditions |
Parameters | Unit | Minimum | Typical | Maximum |
Output current | MA | 0 | 500 | 500 |
Output voltage | V | 11.8 | 12.4 | 12.6 |
Output ripple | MV | |||
Constant current accuracy | % | 1% | 3% | 5% |
AC Input | Output | ||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency |
100 | 1.856 | 12.08 | 100 | 0.618 | 0.65 |
110 | 1.842 | 12.07 | 100 | 0.55 | 0.66 |
120 | 1.826 | 12.06 | 100 | 0.588 | 0.66 |
170 | 1.812 | 12.03 | 100 | 0.533 | 0.66 |
220 | 1.831 | 12 | 100 | 0.493 | 0.66 |
240 | 1.85 | 12 | 100 | 0.479 | 0.65 |
265 | 1.872 | 11.98 | 100 | 0.463 | 0.64 |
AC Input | Output | ||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency |
100 | 5.184 | 12.49 | 300 | 0.62 | 0.72 |
110 | 5.099 | 12.48 | 300 | 0.613 | 0.73 |
120 | 5.025 | 12.46 | 300 | 0.646 | 0.74 |
170 | 4.913 | 12.41 | 300 | 0.606 | 0.76 |
220 | 4.9 | 12.41 | 300 | 0.57 | 0.76 |
240 | 4.913 | 12.41 | 300 | 0.558 | 0.76 |
265 | 4.93 | 12.39 | 300 | 0.544 | 0.75 |
AC Input | Output | ||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency |
100 | 8.139 | 11.8 | 500 | 0.635 | 0.72 |
110 | 8.531 | 12.48 | 500 | 0.63 | 0.73 |
120 | 8.43 | 12.55 | 500 | 0.641 | 0.74 |
170 | 8.112 | 12.5 | 500 | 0.63 | 0.77 |
220 | 8.065 | 12.48 | 500 | 0.6 | 0.77 |
240 | 8.052 | 12.47 | 500 | 0.59 | 0.77 |
265 | 8.076 | 12.46 | 500 | 0.577 | 0.77 |
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Working ambient temperature | ºC | Full load operation | -18 | +40 | +60 |
Storage ambient temperature | ºC | -25 | 25 | +75 |