Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 2.14/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Input parameter:
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Input Voltage | V(AC) | Normal | 85 | 220 | 265 |
Input frequency | HZ | Normal | 50 | 50 | 60 |
Power factor | PF | Normal | 0.427 | 0.671 | 0.705 |
Input Inrush Current | A | Cold start under normal conditions |
Parameters | Unit | Minimum | Typical | Maximum |
Output current | MA | 0 | 2500 | 2500 |
Output voltage | V | 12.01 | 12.01 | 12.23 |
Output ripple | MV | |||
Constant current accuracy | % | 1% | 3% | 5% |
AC Input | Output | ||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency |
85 | 36.52 | 12.01 | 2500 | 0.705 | 0.82 |
100 | 36.01 | 12.01 | 2500 | 0.694 | 0.83 |
110 | 35.80 | 12.01 | 2500 | 0.685 | 0.84 |
120 | 35.63 | 12.01 | 2500 | 0.676 | 0.84 |
170 | 35.37 | 12.01 | 2500 | 0.705 | 0.85 |
220 | 34.96 | 12.01 | 2500 | 0.671 | 0.86 |
240 | 34.94 | 12.01 | 2500 | 0.659 | 0.86 |
265 | 35.19 | 12.01 | 2500 | 0.647 | 0.85 |
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Working ambient temperature | ºC | Full load operation | -18 | +40 | +60 |
Storage ambient temperature | ºC | -25 | 25 | +75 |
Q1: What is your MOQ of power supply?
A: Our MOQ is 5 pieces.
Q2: Can you accept OEM & ODM products, SKD & CKD services?
A: Highly welcome to customize all kinds of electrical power supply OEM & ODM products, and our company provide SKD & CKD services.