Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2years |
Still deciding? Get samples of US$ 0.61/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Input Voltage | V(AC) | Normal | 100 | 220 | 265 |
Input frequency | HZ | Normal | 43 | 50 | 65 |
Power factor | PF | Normal | 0.559 | 0.584 | 0.635 |
Input Inrush Current | A | Cold start under normal conditions |
Parameters | Unit | Minimum | Typical | Maximum |
Output current | MA | 0 | 1000 | 1000 |
Output voltage | V | 5 | 5.14 | 5.45 |
Output ripple | MV | |||
Constant current accuracy | % | 1% | 3% | 5% |
AC Input | Output | ||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency |
100 | 7.16 | 5.22 | 1000 | 0.623 | 0.73 |
110 | 7.1 | 5.22 | 1000 | 0.632 | 0.745 |
120 | 7 | 5.23 | 1000 | 0.635 | 0.75 |
170 | 6.89 | 5.19 | 1000 | 0.615 | 0.75 |
200 | 6.87 | 5.17 | 1000 | 0.596 | 0.75 |
220 | 6.87 | 5.14 | 1000 | 0.584 | 0.75 |
240 | 6.86 | 5.14 | 1000 | 0.573 | 0.75 |
265 | 6.87 | 5.12 | 1000 | 0.559 | 0.75 |
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Working ambient temperature | ºC | Full load operation | -18 | +40 | +60 |
Storage ambient temperature | ºC | -25 | 25 | +75 |