1.Input parameter:
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Input Voltage | V(AC) | Normal | 100 | 220 | 265 |
Input frequency | HZ | Normal | 43 | 50 | 65 |
Power factor | PF | Normal | 0.564 | 0.58 | 0.613 |
Input Inrush Current | A | Cold start under normal conditions |
Parameters | Unit | Minimum | Typical | Maximum |
Output current | MA | 0 | 250 | 250 |
Output voltage | V | 23.3 | 24 | 24.7 |
Output ripple | MV | |||
Constant current accuracy | % | 1% | 3% | 5% |
AC Input | Output | ||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency |
100 | 7.53 | 23.3 | 250 | 0.61 | 0.77 |
110 | 7.84 | 24.5 | 250 | 0.61 | 0.78 |
120 | 7.78 | 24.7 | 250 | 0.613 | 0.79 |
170 | 7.53 | 24.69 | 250 | 0.604 | 0.82 |
220 | 7.44 | 24.6 | 250 | 0.58 | 0.83 |
240 | 7.43 | 24.56 | 250 | 0.573 | 0.83 |
265 | 7.8 | 24.53 | 250 | 0.564 | 0.79 |
Parameters | Unit | Test description | Minimum | Typical | Maximum |
Working ambient temperature | ºC | Full load operation | -18 | +40 | +60 |
Storage ambient temperature | ºC | -25 | 25 | +75 |