Product Description
5V1A Constant Voltage Switching power Supply
Input: AC100-240V
Output: DC5V 1A
Size: 35*16*14mm
Detailed Photos
Certifications
Product Parameters
Main performance indexes:
1.Input parameter:
Parameters |
Unit |
Test description |
Minimum |
Typical |
Maximum |
Input Voltage |
V(AC) |
Normal |
100 |
220 |
265 |
Input frequency |
HZ |
Normal |
43 |
50 |
65 |
Power factor |
PF |
Normal |
0.395 |
0.595 |
0.656 |
Input Inrush Current |
A |
Cold start under normal conditions |
2.Output parameters
Parameters |
Unit |
Minimum |
Typical |
Maximum |
Output current |
MA |
0 |
1000 |
1000 |
Output voltage |
V |
5 |
5 |
5.2 |
Output ripple |
MV |
|
|
|
Constant current accuracy |
% |
1% |
3% |
5% |
3.Overall performance
5V 0.1A test condition
AC Input |
Output |
Input Voltage(V) |
Power consumption(W) |
Output voltage(V) |
Output current(MA) |
Power Factor |
Efficiency |
100 |
0.79 |
5.03 |
100 |
0.497 |
0.64 |
110 |
0.784 |
5.03 |
100 |
0.48 |
0.64 |
120 |
0.776 |
5.03 |
100 |
0.52 |
0.65 |
170 |
0.78 |
5.02 |
100 |
0.463 |
0.64 |
220 |
0.8 |
5.02 |
100 |
0.422 |
0.63 |
240 |
0.811 |
5.01 |
100 |
0.409 |
0.62 |
265 |
0.836 |
5.01 |
100 |
0.395 |
0.6 |
5V 0.5A test condition
AC Input |
Output |
Input Voltage(V) |
Power consumption(W) |
Output voltage(V) |
Output current(MA) |
Power Factor |
Efficiency |
100 |
3.6 |
5.07 |
500 |
0.656 |
0.7 |
110 |
3.55 |
5.06 |
500 |
0.647 |
0.71 |
120 |
3.5 |
5.06 |
500 |
0.635 |
0.72 |
170 |
3.43 |
5.04 |
500 |
0.587 |
0.73 |
220 |
3.43 |
5.04 |
500 |
0.547 |
0.73 |
240 |
3.45 |
5.03 |
500 |
0.533 |
0.73 |
265 |
3.46 |
5.02 |
500 |
0.519 |
0.73 |
5V 1A test condition
AC Input |
Output |
Input Voltage(V) |
Power consumption(W) |
Output voltage(V) |
Output current(MA) |
Power Factor |
Efficiency |
100 |
7.46 |
5.12 |
1000 |
0.636 |
0.69 |
110 |
7.29 |
5.15 |
1000 |
0.645 |
0.71 |
120 |
7.15 |
5.15 |
1000 |
0.65 |
0.72 |
170 |
6.9 |
5.14 |
1000 |
0.628 |
0.74 |
220 |
6.85 |
5.13 |
1000 |
0.595 |
0.75 |
240 |
6.86 |
5.12 |
1000 |
0.584 |
0.75 |
265 |
6.9 |
5.1 |
1000 |
0.571 |
0.74 |
4.Using environment Parameters
Parameters |
Unit |
Test description |
Minimum |
Typical |
Maximum |
Working ambient temperature |
ºC |
Full load operation |
-18 |
+40 |
+60 |
Storage ambient temperature |
ºC |
|
-25 |
25 |
+75 |
5.Description of product certification
3C certification,CE certification
Packaging & Shipping
Company Profile
FAQ